Watts 22c actuator wiring diagram. Main page technical support user manual and instructions hydronic radiant heating solutions installation manual | 22c, 22cx, 22cx5. The best way is to physically check, but it sounds like it. Optional transformer for 277, 380, 575 or 600 volts (120v actuator required) blue 24v single voltage actuator 460v single voltage actuator white brown brown 110/115/120v dual voltage actuators blue 208/220/230/240v dual voltage actuators. Remove the protective cap, if present, or handwheel from the valve (or manifold outlet) 2.
The first way was to wire directly off the valve control system (taco zvc404) to open the valve and also to trigger the end switch to the circulator pump to immediately start. Actuators are normally closed and will open when power is applied. Specifications actuators are normally closed and will open when power is applied. 4 f zone valves zone control type part number size body kvs box qty vu02f vu0220 3/4 ff 4,3 1 vu02f vu0225 1 ff 6,5 1.
Travel time for the actuators is approximately 90 seconds to close the end switch. On/off operation with actuators series 22c, 10c, 20c. The actuator is receiving power but the motor does not respond. 22c series electrothermal actuator 22c series watts brand on/off action, compatible with radiator valves, fan coil valves and manifolds.
It has a diagram of a blue and brown wire going to the motor on the front. A wiring diagram is included inside the cover for easy reference. To close the end switch. Connect the wires to the power supply 4.
Verify the line voltage into the actuator via the field connections and insure that it matches the rating on the nameplate of the actuator. Insert the plug in the actuator connector installation Two for power, two for an end switch (see wiring diagrams). Failure to do so will cause the actuator to operate out of its normal 90 degree rotation.
Check internal actuator wiring against the wiring diagram supplied with the actuator. The terminal strip has been placed near the two conduit entries with ample room for running wire leads. Travel time for the actuators are approximately 90 sec. Cani assume that it's 2 wire?
Wiring direct to battery not recommended. Watts radiant thermal actuators are a four wire actuator designed to be used with watts radiant stainless steel and cast brass manifolds. This article describes how to wire up heating zone valves. Each actuator has four wires:
Each actuator must be powered through its own individual switch contacts to avoid cross feed. D/a or r/a option jumper selectable. Direct replacement (same wiring dimensions & thread) for: Two for power, two for an end switch (see wiring diagrams).
To install the actuators follow these steps: Available both in no (normally open) and nc (normally closed) versions. Each actuator has four wires: Can be used both as mixing and
Install actuator after ignition switch, or master power switch. Actuators are normally closed and will open when power is applied. Zone valve wiring diagram l. Proportional nc valve actuator emuwe series.
Wiring diagram room thermostat milux, actuator, pump manual programmable wired room thermostat milux2 with 2 batteries manual programmable wired room thermostat milux2 230v Installation manual | 22c, 22cx, 22cx5. 4 wire actuators are used on small manifolds as it means you can avoid using a wiring centre. Travel time for the actuators is approximately 90 seconds to close the end switch.
![KHS CoolFlow cold water regulatingvalve, with 230 V](https://i2.wp.com/produktkatalog.kemper-olpe.de/media/en/ZEI_PRO_SCH_6150G015_SALL_AING_V1.jpg)
KHS CoolFlow cold water regulatingvalve, with 230 V
![Electrothermic actuator 22C](https://i2.wp.com/wattswater.eu/upload/iblock/0ed/22C.jpg)
Electrothermic actuator 22C
![Horne 20 Thermostatic Mixing Valve H2022C](https://i2.wp.com/www.horne.co.uk/media/2588/h20-22c_1200x800.jpg)
Horne 20 Thermostatic Mixing Valve H2022C
![Horne 15 thermostatic mixing valve with integral isolating](https://i2.wp.com/www.horne.co.uk/media/2941/h15-22c_1200x800.jpg)
Horne 15 thermostatic mixing valve with integral isolating
![Nickelplated thermostatic valve 131SN](https://i2.wp.com/wattswater.nu/upload/iblock/1dd/131SN_WEB.jpg)
Nickelplated thermostatic valve 131SN
Water heater manual Underfloor heating manifold schematic
![Watts Actuator 22C, Normally Closed Floor Heating Direct](https://i2.wp.com/floorheating-direct.co.uk/wp-content/uploads/2020/05/install-actuator-1.jpg)
Watts Actuator 22C, Normally Closed Floor Heating Direct
![Horne 20 Thermostatic Mixing Valve H2022C](https://i2.wp.com/www.horne.co.uk/media/2182/h20-22_1200x800.gif)
Horne 20 Thermostatic Mixing Valve H2022C
![Patent US7854239 High temperature valve Google Patentsuche](https://i2.wp.com/patentimages.storage.googleapis.com/US7854239B2/US07854239-20101221-D00011.png)
Patent US7854239 High temperature valve Google Patentsuche
![Nickelplated thermostatic valve 1134M](https://i2.wp.com/wattswater.eu/upload/iblock/351/1134m.png)
Nickelplated thermostatic valve 1134M
![6563 TwisTop™ Thermoelectric Actuator Caleffi USA](https://i2.wp.com/www.caleffi.com/sites/default/files/styles/product_photo/public/file/6563.jpg?itok=XK-e_LeY)
6563 TwisTop™ Thermoelectric Actuator Caleffi USA
![Electrothermic Actuator Product Catalog](https://i2.wp.com/www.gfps.com/appgate/ecat/common_flow/10002H/data/shared/pool/880717/web560x400.jpg)
Electrothermic Actuator Product Catalog
![Woodford 22C4MHSF Woodford 22C4MHSF Horizontal](https://i2.wp.com/images2.plumbersstock.com/750/750/509968.jpg)
Woodford 22C4MHSF Woodford 22C4MHSF Horizontal
![Reverse Osmosis Accessories Water Purification Supplies](https://i2.wp.com/waterpurificationsupplies.com/wp-content/uploads/2019/06/Shut-Off-Valve.jpg)
Reverse Osmosis Accessories Water Purification Supplies
![3Way Valve by BuTech Pneumatic and Hydraulic](https://i2.wp.com/pneumaticandhydraulic.com/wp-content/uploads/Butech-3-way-valve.jpg)
3Way Valve by BuTech Pneumatic and Hydraulic
![Siemens CMV322 MidPosition Motorised Valve](https://i2.wp.com/www.heatingcontrolsonline.co.uk/image/cache/data/images/09hh4-1000x1000.jpg)
Siemens CMV322 MidPosition Motorised Valve
![Watts Actuator 22C, Normally Closed Floor Heating Direct](https://i2.wp.com/floorheating-direct.co.uk/wp-content/uploads/2020/05/92039_4.jpg)
Watts Actuator 22C, Normally Closed Floor Heating Direct
![Underfloor Heating Actuator 24V 4 Wire N/C Watts 22C](https://i2.wp.com/underfloorparts.co.uk/wp-content/uploads/2019/02/Watts24vWire4.jpg)
Underfloor Heating Actuator 24V 4 Wire N/C Watts 22C
![Nickelplated thermostatic valve 134M](https://i2.wp.com/wattswater.be/upload/iblock/612/134m.png)
Nickelplated thermostatic valve 134M
![Figure 22. Check valve assembly and safety relief valve](https://i2.wp.com/compressors.tpub.com/TM-5-4310-241-15/TM-5-4310-241-150106im.jpg)
Figure 22. Check valve assembly and safety relief valve
![Belimo Products are Certified to UL 2043 Informed](https://i2.wp.com/informedinfrastructure.com/wp-content/uploads/2021/06/Belimo-e1622652602734.png)
Belimo Products are Certified to UL 2043 Informed
![Watts 22CX Actuator Head 24V 2 Wire N/C 22CX24NC2](https://i2.wp.com/underfloorparts.co.uk/wp-content/uploads/2018/02/Watts24v.jpg)
Watts 22CX Actuator Head 24V 2 Wire N/C 22CX24NC2
![Bathroom Side Entry Toilet Spare Parts Fill Valve](https://i2.wp.com/www.htdsanitary.com/wp-content/uploads/2017/07/AB-26B6-22CC4821.jpg)
Bathroom Side Entry Toilet Spare Parts Fill Valve
![Additional Material OpenMotics](https://i2.wp.com/wiki.openmotics.com/images/e/e4/Watts_Actuator.jpg)
Additional Material OpenMotics
![Frigidaire FGUS2642LF0 Refrigerator Parts and Accessories](https://i2.wp.com/www.partswarehouse.com/v/vspfiles/assets/images/Frigidaire/FGUS2642LF0/FGUS2642LF0-3.png)
Frigidaire FGUS2642LF0 Refrigerator Parts and Accessories